Emergency Fire Exit Door Provider

I am text block. Click edit button to change this text. Lorem ipsum dolor sit amet, consectetur adipiscing elit. Ut elit tellus, luctus nec ullamcorper mattis.

MEK Emergency Fire Exit Doors

MEK Pakistan’s UL1003 Emergency Exit Door with Panic Bar  provides excellent has excellent fire safety ratings and is available at an affordable price. CDF stocks most fire doors including popular 45 minute 90 minute and 3hr ratings.

  • Heavy Duty, Front Gauge Steel sheet as per rating.
  • Rockwool filled within door thickness.
  • Widths up to 4’0″, Height to 8’0″to meet clients’ size requirements.
  • Double Door Configurations available for width above 4’.
  • 45-75 mm Door Thickness.
  • Heavy Duty Door Closer.

MEK Emergency Exit Doors and Fire Rated Doors

  • Door is normally locked
  • Access is gained by a valid credential
  • Free egress is available at all times
 

Within the meaning of these standards, emergency exit door systems are subdivided in emergency exit devices according to EN 179, and panic door Exit devices according to EN 1125. Emergency exits acc. to EN 179 are designated to buildings to which the general public does not have access and whose visitors understand the function of the emergency doors. Panic door exit devices acc. to EN 1125 are used in public buildings where the visitors are not familiar with the function of emergency doors, like schools, hospitals, shopping malls. The MEK door systems offer a comprehensive range of applications, which can also be combined with other functions and design options.

MEK Red Emergency Exit Doors

  • Fire exit doors must open from inside without keys, tools, or special knowledge.
  • The fire exit doors must open outwards.
  • Fire exit doors must not be revolving or sliding.
  • A nationally recognized testing laboratory must approve all Fire exit doors.
  • Exit routes must have adequate emergency lighting.
  • Line of sight to an exit sign must be clear.
  • Each exit must have a distinctive sign that says “Exit” marked in letters that are at least 6 inches height with a ¾ inch stroke width.
  • Fire exit doors must have no signs or furnishings that obscure their visibility.

MEK Emergency Exit Doors

  • Heavy Duty, Front Gauge Steel sheet as per rating.
  • Rockwool filled within door thickness.
  • Widths up to 4’0″, Height to 8’0″to meet clients’ size requirements.
  • Double Door Configurations available for width above 4’.
  • 45-75 mm Door Thickness.
  • Heavy Duty Door Closer.
  • Reinforcement Clips and/or Channels for Glass Cutouts.
  • Factory Applied Anti-Rust Primer (Color as per clients’ requirement).
  • It is recommended that finish paint (top coat) be applied after installation.
  • Standard Lock.